Gap measurement of tripping pins
When triggering a switching operation in test equipment for camshafts, a tripping pin is moved at high speed. A gap measurement detects whether the tripping pin has been completely extended and if it has been triggered with the required speed. Evaluation of the displacement-time-signal determines all parameters reliably. The optoCONTROL 1200/90 optical micrometer carries out these measurements.